38 research outputs found

    Neuromuscular Control Strategy during Object Transport while Walking: Adaptive Integration of Upper and Lower Limb Movements

    Get PDF
    When carrying an object while walking, a significant challenge for the central nervous system (CNS) is to preserve the object’s stability against the inter-segmental interaction torques and ground reaction forces. Studies documented several strategies used by the CNS: modulation of grip force (GF), alterations in upper limb kinematics, and gait adaptations. However, the question of how the CNS organizes the multi-segmental joint and muscle coordination patterns to deal with gait-induced perturbations remains poorly understood. This dissertation aimed to explore the neuromuscular control strategy utilized by the CNS to transport an object during walking successfully. Study 1 examined the inter-limb coordination patterns of the upper limbs when carrying a cylinder-shaped object while walking on a treadmill. It was predicted that transporting an object in one hand would affect the movement pattern of the contralateral arm to maintain the overall angular momentum. The results showed that transporting an object caused a decreased anti-phase coordination, but it did not induce significant kinematic and muscle activation changes in the unconstrained arm. Study 2 examined muscle synergy patterns for upper limb damping behavior by using non-negative matrix factorization (NNMF) method. Four synergies were identified, showing a proximal-to-distal pattern of activation preceding heel contacts. Study 3 examined the effect of different precision demands (carrying a cup with or without a ball) and altered visual information (looking forward vs. looking at an object) on the upper limb damping behavior and muscle synergies. Increasing precision demand induced stronger damping behavior and increased the electromyography (EMG) activation of wrist/hand flexors and extensors. The NNMF results replicated Study 2 in that the stabilization of proximal joints occurred before the distal joints. The results indicated that the damping incorporates tonic and phasic muscle activation to ensure object stabilization. Overall, three experiments showed that the CNS adopts a similar synergy pattern regardless of task constraint or altered gaze direction while modulating the amount of muscle activation for object stabilization. Kinematic changes can differ depending on the different levels of constraint, as shown in the smaller movement amplitude of the shoulder joint in the transverse plane during the task with higher precision demand

    Small-scale, semi-automated purification of eukaryotic proteins for structure determination

    Get PDF
    A simple approach that allows cost-effective automated purification of recombinant proteins in levels sufficient for functional characterization or structural studies is described. Studies with four human stem cell proteins, an engineered version of green fluorescent protein, and other proteins are included. The method combines an expression vector (pVP62K) that provides in vivo cleavage of an initial fusion protein, a factorial designed auto-induction medium that improves the performance of small-scale production, and rapid, automated metal affinity purification of His8-tagged proteins. For initial small-scale production screening, single colony transformants were grown overnight in 0.4 ml of auto-induction medium, produced proteins were purified using the Promega Maxwell 16, and purification results were analyzed by Caliper LC90 capillary electrophoresis. The yield of purified [U-15N]-His8-Tcl-1 was 7.5 μg/ml of culture medium, of purified [U-15N]-His8-GFP was 68 μg/ml, and of purified selenomethione-labeled AIA–GFP (His8 removed by treatment with TEV protease) was 172 μg/ml. The yield information obtained from a successful automated purification from 0.4 ml was used to inform the decision to scale-up for a second meso-scale (10–50 ml) cell growth and automated purification. 1H–15N NMR HSQC spectra of His8-Tcl-1 and of His8-GFP prepared from 50 ml cultures showed excellent chemical shift dispersion, consistent with well folded states in solution suitable for structure determination. Moreover, AIA–GFP obtained by proteolytic removal of the His8 tag was subjected to crystallization screening, and yielded crystals under several conditions. Single crystals were subsequently produced and optimized by the hanging drop method. The structure was solved by molecular replacement at a resolution of 1.7 Å. This approach provides an efficient way to carry out several key target screening steps that are essential for successful operation of proteomics pipelines with eukaryotic proteins: examination of total expression, determination of proteolysis of fusion tags, quantification of the yield of purified protein, and suitability for structure determination

    Reversibly controlled ternary polar states and ferroelectric bias promoted by boosting square???tensile???strain

    Get PDF
    Interaction between dipoles often emerges intriguing physical phenomena, such as exchange bias in the magnetic heterostructures and magnetoelectric effect in multiferroics, which lead to advances in multifunctional heterostructures. However, the defect-dipole tends to be considered the undesired to deteriorate the electronic functionality. Here, we report deterministic switching between the ferroelectric and the pinched states by exploiting a new substrate of cubic perovskite, BaZrO3, which boosts square-tensile-strain to BaTiO3 and promotes four-variants in-plane spontaneous polarization with oxygen vacancy creation. First-principles calculations propose a complex of an oxygen vacancy and two Ti3+ ions coins a charge-neutral defect-dipole. Cooperative control of the defect-dipole and the spontaneous polarization reveals ternary in-plane polar states characterized by biased/pinched hysteresis loops. Furthermore, we experimentally demonstrate that three electrically controlled polar-ordering states lead to switchable and non-volatile dielectric states for application of non-destructive electro-dielectric memory. This discovery opens a new route to develop functional materials via manipulating defect-dipoles and offers a novel platform to advance heteroepitaxy beyond the prevalent perovskite substrates

    Trunk Extensor Force Modulation

    No full text
    Data related to the trunk muscle extensor force modulation test-retest reliability and construct validity cross-sectional study

    MRI Compatible Lumbopelvic Movement Measurement System

    No full text

    Test-retest reliability and construct validity of trunk extensor muscle force modulation accuracy.

    No full text
    Low back pain is associated with changes in trunk muscle structure and function and motor control impairments. Voluntary force modulation (FM) of trunk muscles is a unique and under-investigated motor control characteristic. One of the reasons for this paucity of evidence is the lack of exploration and publication on the reliability and validity of trunk FM protocols. The purpose of this study was to determine the within- and between-day test-retest reliability and construct validity for trunk extensor muscle FM. Twenty-nine healthy participants were tested under three FM conditions with different modulation rates. Testing was performed on a custom-built apparatus designed for trunk isometric force testing. FM accuracy relative to a fluctuating target force (20-50%MVF) was quantified using the root mean square error of the participant's generated force relative to the target force. Reliability and precision of measurement were assessed using the Intraclass Correlation Coefficient (ICC), standard error of measurement (SEM), minimal detectable difference (MDD95), and Bland-Altman plots. In a subset of participants, we collected surface electromyography of trunk and hip muscles. We used non-negative matrix factorization (NNMF) to identify the underlying motor control strategies. Within- and between-day test-retest reliability was excellent for FM accuracy across the three conditions (ICC range: 0.865 to 0.979). SEM values ranged 0.9-1.8 Newtons(N) and MDD95 ranged from 2.4-4.9N. Conditions with faster rates of FM had higher ICCs. NNMF analysis revealed two muscle synergies that were consistent across participants and conditions. These synergies demonstrate that the muscles primarily involved in this FM task were indeed the trunk extensor muscles. This protocol can consistently measure FM accuracy within and between testing sessions. Trunk extensor FM, as measured by this protocol, is not specific to any trunk muscle group but is the result of modulation by all the trunk extensor muscles

    Characteristics of study participants.

    No full text
    Low back pain is associated with changes in trunk muscle structure and function and motor control impairments. Voluntary force modulation (FM) of trunk muscles is a unique and under-investigated motor control characteristic. One of the reasons for this paucity of evidence is the lack of exploration and publication on the reliability and validity of trunk FM protocols. The purpose of this study was to determine the within- and between-day test-retest reliability and construct validity for trunk extensor muscle FM. Twenty-nine healthy participants were tested under three FM conditions with different modulation rates. Testing was performed on a custom-built apparatus designed for trunk isometric force testing. FM accuracy relative to a fluctuating target force (20–50%MVF) was quantified using the root mean square error of the participant’s generated force relative to the target force. Reliability and precision of measurement were assessed using the Intraclass Correlation Coefficient (ICC), standard error of measurement (SEM), minimal detectable difference (MDD95), and Bland-Altman plots. In a subset of participants, we collected surface electromyography of trunk and hip muscles. We used non-negative matrix factorization (NNMF) to identify the underlying motor control strategies. Within- and between-day test-retest reliability was excellent for FM accuracy across the three conditions (ICC range: 0.865 to 0.979). SEM values ranged 0.9–1.8 Newtons(N) and MDD95 ranged from 2.4–4.9N. Conditions with faster rates of FM had higher ICCs. NNMF analysis revealed two muscle synergies that were consistent across participants and conditions. These synergies demonstrate that the muscles primarily involved in this FM task were indeed the trunk extensor muscles. This protocol can consistently measure FM accuracy within and between testing sessions. Trunk extensor FM, as measured by this protocol, is not specific to any trunk muscle group but is the result of modulation by all the trunk extensor muscles.</div

    S1 Checklist -

    No full text
    Low back pain is associated with changes in trunk muscle structure and function and motor control impairments. Voluntary force modulation (FM) of trunk muscles is a unique and under-investigated motor control characteristic. One of the reasons for this paucity of evidence is the lack of exploration and publication on the reliability and validity of trunk FM protocols. The purpose of this study was to determine the within- and between-day test-retest reliability and construct validity for trunk extensor muscle FM. Twenty-nine healthy participants were tested under three FM conditions with different modulation rates. Testing was performed on a custom-built apparatus designed for trunk isometric force testing. FM accuracy relative to a fluctuating target force (20–50%MVF) was quantified using the root mean square error of the participant’s generated force relative to the target force. Reliability and precision of measurement were assessed using the Intraclass Correlation Coefficient (ICC), standard error of measurement (SEM), minimal detectable difference (MDD95), and Bland-Altman plots. In a subset of participants, we collected surface electromyography of trunk and hip muscles. We used non-negative matrix factorization (NNMF) to identify the underlying motor control strategies. Within- and between-day test-retest reliability was excellent for FM accuracy across the three conditions (ICC range: 0.865 to 0.979). SEM values ranged 0.9–1.8 Newtons(N) and MDD95 ranged from 2.4–4.9N. Conditions with faster rates of FM had higher ICCs. NNMF analysis revealed two muscle synergies that were consistent across participants and conditions. These synergies demonstrate that the muscles primarily involved in this FM task were indeed the trunk extensor muscles. This protocol can consistently measure FM accuracy within and between testing sessions. Trunk extensor FM, as measured by this protocol, is not specific to any trunk muscle group but is the result of modulation by all the trunk extensor muscles.</div

    Group averaged muscle synergies extracted by non-negative matrix factorization.

    No full text
    Temporal patterns and weighting coefficients (+SD) for three different conditions. Synergies presented in the same color between conditions indicate the same synergies with the mean scalar product greater than 0.85. The scalar products calculated compared to the synergies in condition A are presented on the graphs of conditions B and C, indicating the similarity between those synergies across conditions. SYN, synergy; LTES, left thoracic erector spinae; RTES, right thoracic erector spinae; LLES, left lumbar erector spinae; RLES, right lumbar erector spinae; LLM, left lumbar multifidus; RLM, right lumbar multifidus; LGMX, left gluteus maximus; RGMX, right gluteus maximus; LEO, left external oblique; REO, right external oblique.</p
    corecore